Mfg Part Number: D381-CM40416 | Alternate P/N: D381CM40416 | Manufacturer: Clarostat Sensors And Controls |
NSN : 5905-01-050-8176 | Item Name : Resistor Variable Nonwire Wound | CAGE Code : 12697 |
FSC : 5905 Resistors |
Welcome to The Aviation Mart, your parts purchasing partner with hot part numbers like D381-CM40416 by Clarostat Sensors And Controls. Here, you can find an array of Resistor Variable Nonwire Wound components, such as the NSN 5905-01-050-8176, which is immediately available for procurement. At The Aviation Mart, we subject our stock to varying levels of quality assurance measures, tests, verifications, and assessments, allowing us to verify the high caliber of our offerings. As an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, customers can trust in the integrity of our offerings as we only source items from entities on our Approved Vendor List (AVL).
Explore our wide-ranging database at your leisure and submit a quote request on part D381-CM40416 or any highly sought-after NSN including 5905-01-050-8176 or any other with ease. More than that, we carry leading brand names like Clarostat Sensors And Controls, of which we stock popular CAGE Codes such as 12697. Backed by unmatched turnaround times and unbeatable cost savings on thousands of items, we leverage our purchasing power and market expertise to bring you the best possible solutions for even the most rigid operational restraints. For additional questions about NSN parts or other items, call or email us at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-050-8176 Item Description: Resistor Variable Nonwire Wound | 5905 | 010508176 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
D381-Cm40416 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 2 |
AAQL | BODY STYLE | CYLINDRICAL BUSHING MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.937 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.812 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 1.000 INCHES NOMINAL |
ADAP | MOUNTING BUSHING LENGTH | 0.375 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.812 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 1.062 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND |
AEEA | SWITCH TYPE | ROTARY |
AEED | SWITCH VOLTAGE RATING IN VOLTS | 120.0 |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 300.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 0.80 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 64.00 INCH-OUNCES |
AEFN | NONTURN DEVICE LOCATION | AT 3 OCLOCK |
AEFP | NONTURN DEVICE RADIUS | 0.469 INCHES NOMINAL |
AEGH | SWITCH OPERATING POSITION | START OF ROTATION |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN, BOTH POSITIONS MAINTAINED |
AJYN | SCREW THREAD DIAMETER | 0.375 INCHES NOMINAL |
AJYP | SCREW THREAD SERIES DESIGNATOR | UNEF |
AJYQ | SCREW THREAD QUANTITY PER INCH | 32.0 |
APXH | TERMINAL LOCATION | REAR-BOTTOM |
AXGY | MOUNTING METHOD | STANDARD BUSHING |
CBBL | FEATURES PROVIDED | SWITCH |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 400.0 PERCENT, RATED AMPERES C AND BETTER INDUSTRIAL CLEARS |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 75.0 PERCENT, RATED AMPERES C AND BETTER FINISH |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 300.0 NOMINAL |
CQDB | RESISTANCE TEMP CHARACTERISTIC RANGE PER SECTION IN PERCENT | +0.0/+7.0 -55 DEG CELSIUS 1ST SECTION AND +0.5/+3.5 -25 DEG CELSIUS 1ST SECTION AND +0.0/+2.0 0 DEG CELSIUS 1ST SECTION AND -2.5/+2.5 85 DEG CELSIUS 1ST SECTION AND +0.0/+5.0 120 DEG CELSIUS 1ST SECTION |
CQDB | RESISTANCE TEMP CHARACTERISTIC RANGE PER SECTION IN PERCENT | +0.0/+8.0 -55 DEG CELSIUS 2ND SECTION AND +0.0/+4.0 -25 DEG CELSIUS 2ND SECTION AND +0.0/+2.0 0 DEG CELSIUS 2ND SECTION AND -3.0/+3.0 85 DEG CELSIUS 2ND SECTION AND +0.0/+6.0 120 DEG CELSIUS 2ND SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.15/+0.15 2ND SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.25/+0.25 1ST SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 105.0 ALL SECTIONS |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR ALL SECTIONS |
CRGM | FUNCTION CONFORMITY PER SECTION | ALL SECTIONS INDEPENDENT LINEARITY |
CRJS | FIXED TAP QUANTITY PER SECTION | 1 2ND SECTION |
CRJS | FIXED TAP QUANTITY PER SECTION | 2 1ST SECTION |
CRKS | TAP LOCATION TOLERANCE PER SECTION | -1.0/+1.0 OHMS ALL SECTIONS |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 1ST SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0/+20.0 2ND SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 200000.0 2ND SECTION |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 30000.0 1ST SECTION AND 50500.0 1ST SECTION |
CSBX | FUNCTION CHARACTERISTIC PER SECTION | ALL SECTIONS LINEAR |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 ALL SECTIONS |
CSDK | SWITCH CURRENT TYPE AND RATING IN AMPS | 2.500 AC |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB, SOLDER LUG |
![]() |