Mfg Part Number: 400932 | Manufacturer: Curtiss Wright Controls Inc | NSN : 5950-00-069-8161 |
Item Name : Transformer Power | CAGE Code : 0AHP5 | FSC : 5950 Coils and Transformers |
Welcome to The Aviation Mart, your parts purchasing partner with hot part numbers like 400932 by Curtiss Wright Controls Inc. Here, you can find an array of Transformer Power components, such as the NSN 5950-00-069-8161, which is immediately available for procurement. At The Aviation Mart, we subject our stock to varying levels of quality assurance measures, tests, verifications, and assessments, allowing us to verify the high caliber of our offerings. As an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, customers can trust in the integrity of our offerings as we only source items from entities on our Approved Vendor List (AVL).
Explore our wide-ranging database at your leisure and submit a quote request on part 400932 or any highly sought-after NSN including 5950-00-069-8161 or any other with ease. More than that, we carry leading brand names like Curtiss Wright Controls Inc, of which we stock popular CAGE Codes such as 0AHP5. Backed by unmatched turnaround times and unbeatable cost savings on thousands of items, we leverage our purchasing power and market expertise to bring you the best possible solutions for even the most rigid operational restraints. For additional questions about NSN parts or other items, call or email us at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-069-8161 Item Description: Transformer Power | 5950 | 000698161 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
400932 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.750 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.125 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY AND 1.25 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY AND 1.375 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 112.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY AND 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY AND 137.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.15 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY AND 3.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY AND 3.85 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 0.25 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 76.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 84.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.25 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 56.25 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 68.75 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.25 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 22.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 27.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 112.10 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 118.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 123.90 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 3.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 22.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 27.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 21 TAB, SOLDER LUG |
![]() |